16 Maxim Integrated
USB Battery Charger Detectors
MAX14578E/MAX14578AE
Figure 3 shows D+/D- terminations for a standard USB
host/charging downstream port, an Apple charger, a
Sony charger, and a dedicated charger.
Charger-Enable Control Outputs
The MAX14578E/MAX14578AE feature digital open-drain
outputs—CE0 (MAX14578AE only), CE1, and CE2—to
control an external charger autonomously. See Table 3.
Figure 3. Standard USB Host/Charging Downstream Port, Apple Charger, Sony Charger, and Dedicated Charger
Table 3. Charger-Enable Control Outputs
Note: When CE_FRC = 1, CE[2:0] are set by an I
2
C command.
X = Don’t care.
V
LOAD
PU
3.6V
STANDARD USB
HOST CHARGING
DOWNSTREAM PORT
HLPU
300k
HPD
14.25k TO 24.8k
D+
V
LOAD
PU
3.6V
HLPU
300k
HPD
14.25k TO 24.8k
D-
V
BUS
5.0V
APPLE CHARGER
ADPPU
75.0k
ADPPD
49.9k
D+
V
BUS
5.0V
ADMPU
43.2k (FOR 1A)
75.0k (FOR 0.5A)
ADMPD
49.9k
D-
V
BUS
5.0V
SONY CHARGER
SDPPU
5.1k
SDPPD
10k
D+
V
BUS
5.0V
SDPPU
5.1k
SDPPD
10k
D-
V
BUS
5.0V
DEDICATED CHARGER
2M
(MIN)
D+
2M
(MIN)
D-
SUS_LOW
EN
CHG_TYP USB_CPL CE2 CE1 CE0
0 1 X X 1 1 1
1 1 X X 0 0 1
0 0 000 X 1 1 1
1 0 000 X 0 0 1
0 0 110 X 1 1 1
1 0 110 X 0 0 1
X 0 001 0 1 0 0
0 0 001 1 1 1 1
1 0 001 1 0 0 1
X 0 010 X 0 1 0
X 0 011 X 0 1 0
X 0 100 X 1 0 0
X 0 101 X 0 1 0
X 0 111 X 0 0 0