8 Maxim Integrated
USB Battery Charger Detectors
MAX14578E/MAX14578AE
Bump Configuration
Bump Description
TOP VIEW
(BUMP SIDE DOWN)
A
B
C
() MAX14578AE ONLY.
() MAX14578AE ONLY.
*CONNECT EP TO GND.
WLP
2413
+
CD+ CD- V
B
INT
(LOUT)
GND
SCL
(EN)
SDA
(CE0)
CE1
TD+ TD- BAT CE2
MAX14578E/MAX14578AE
15
16
14
13
5
6
7
N.C.
CD+
8
TD+
N.C.
(LOUT_SNS)
INT
(LOUT)
CE2
13
SCL
(EN)
4
12 10 9
TD-
N.C.
V
B
BAT
CD-
GND
EP*
N.C. CE1
2
11
SDA
(CEO)
TQFN
MAX14578E
MAX14578AE
TOP VIEW
+
PIN
NAME FUNCTION
MAX14578E MAX14578AE
TQFN-EP WLP TQFN-EP WLP
1 C1 1 C1 TD+ USB Transceiver D+ Connection
2, 3,
10, 16
— 2, 3, 16 — N.C. No Connection. Not internally connected.
4 A1 4 A1 CD+ USB Connector D+ Connection
5 B1 5 B1 GND Ground
6 A2 6 A2 CD- USB Connector D- Connection
7 C3 7 C3 BAT
Battery Connection Input. Connect a 1FF capacitor as close as possible
between BAT and GND.
8 A3 8 A3 V
B
USB Connector V
BUS
Connection. Connect a 1FF capacitor as close
as possible between V
B
and GND for Q15kV ESD protection.
9 A4 — — INT Active-Low Interrupt Request, Open-Drain Output
— — 9 A4 LOUT
+5.3V USB Transceiver V
BUS
Power Output. Connect a 1FF capacitor
as close as possible between LOUT and GND.
— — 10 — LOUT_SNS Connect Externally to LOUT (MAX14578AE, TQFN Only)
11 B4 11 B4 CE1 Charger-Enable Control 1, Open-Drain Output
12 C4 12 C4 CE2 Charger-Enable Control 2, Open-Drain Output
13 B3 — — SDA
I
2
C Serial-Data Input/Output. Connect SDA to an external pullup
resistor.
— — 13 B3 CE0 Charger-Enable Control 0, Open-Drain Output
— — 14 B2 EN
Active-Low Enable Input. Drive EN low to enable the charger ID
detection and close the USB switches after charger detection is
complete.