Chapter 3 Installing Your Server in a Rack 27
Determine the Position for the Server in the Rack
Review the guidelines for positioning the server in the rack (see “Guidelines for Server
Installation on page 21). Then follow these steps to measure and mark its specific
location.
1 Determine the exact position where you want to attach the server and mark it on one
side of the rack.
Some racks have marks at regular intervals (such as 1U) to aid in positioning a server;
others may provide a template to help place the server in the rack. If your rack does not
have such aids, measure or count holes from an established point.
The distance between holes may vary somewhat on racks made by different
manufacturers.
2 Use the mounting template or a straightedge to mark the same spot on the other side
of the rack.
You can put a pencil mark or a piece of tape on each side of the rack to mark the
correct spot.
For a four-post rack, measure and mark the posts at the front and back.
3 To verify that the position is correct, measure 1.75 inches (the servers height) down
from the hole you’ve marked on the rack.
You measure downward because you’ll attach the cover of the servers enclosure to the
rack, then slide the server into it.
Identify the
appropriate holes
in all mounting posts
before you install the
server so that it is
mounted level.